
149
3 Avitech ASCII Protocol
The Rainier 3G supports the ASCII command prompt interface. The serial port
(RS-232) and Ethernet port (IP) on the Rainier 3G can also be used to interface for
control over RS-232 / IP. This chapter familiarizes you with using the Avitech
ASCII Protocol (AAP) of the Rainier 3G.
3.1 Setting the RS-232 Port
Before using the ASCII X command via the RS-232 interface, make sure that the
COM (RS-232) port on the computer is set at Normal (8-bit data, 1 stop bit, no
parity, and no flow control). The default baud rate is 57600 bps (configurable).
To use the ASCII X commands, use the Phoenix-Q software to correctly set the
Group and Module Number of the Rainier 3G.
Commentaires sur ces manuels